Every pilot, valve and vent in the building, one unit at a time
Plan a building round
Give us the building and roughly how many fireplaces it holds. We call back with a plan.
The gas checklist we run in each unit
Gas fireplaces fail quietly. A pilot that burns lazy, a vent cap packed with leaves, a glass front that has come off its latches: none of these makes a noise, and a tenant who uses the fireplace a few nights a year will not notice. So every unit gets the same list, in the same order, and the result goes on that unit's page.
- Pilot lit, steady and mostly blue, with the burner catching cleanly from it
- Shutoff valve reachable and turning freely
- Glass front latched down, seals whole, no cracks or chips
- Screen or barrier in front of the glass where the model calls for one
- Vent cap outside clear, undamaged and away from windows and doors
- Carbon monoxide level in the room with the burner running
- Smoke and CO alarms present and working in the unit
Where wood comes into it
Older buildings around South Gate and Huntington Park often mix the two: gas logs in most units and a working wood fireplace in a few, or a common room with a real hearth. Those flues build creosote the gas ones never see, and they need a sweep on a schedule that follows how much they are burned.
Tenants are part of the picture. Someone burning pallet wood or trash in a unit fireplace, or burning on a South Coast AQMD no-burn day, is a problem for the building as much as for them. We note what we find in the firebox so the manager has something concrete to raise.
What the manager or board receives
Each fireplace gets its own dated page: unit number, fireplace type, what was checked, what passed, what failed and photos. On top sits a one page summary for the whole building with the urgent items first, the wear items next and the passes last.
Those pages are what an insurer, a lender or an incoming board member tends to ask for, and they make next year's round faster because we start from what we saw last time.
Getting into the units
Entry is the manager's arrangement, made with notice to each tenant. We work from a unit list in the order you give us, and any unit we cannot get into is marked as missed on the summary rather than dropped. A unit with the fireplace blocked by furniture gets the same note.
One price per fireplace
A building with twenty gas units costs twenty visual checks. A unit that needs the camera or a sweep gets that line on top.
- Visual check, each gas or wood fireplace
- $57
- Camera inspection where a unit needs it
- $405
- Sweep for a wood-burning flue
- from $435
Gas repairs found on the round, such as a failed pilot assembly or a cracked glass front, get a written price per unit before any work.
Questions from managers and boards
Do gas fireplaces really need checking?
Yes. The burner is clean, but the vent still carries exhaust out of the unit, and nests, crushed vent pipe or a loose glass front can send it into the room instead.
What happens if a unit smells of gas?
We stop work in that unit, close the fireplace valve if it can be reached safely, and the occupants leave while the gas company is called. Nothing is relit until the utility has cleared it.
A few tenants have wood stoves. Can you look at those too?
Yes. Stoves get the same per fireplace check plus a look at clearances, the hearth pad and the connector pipe, and a sweep if the flue needs one.
Can the records go to our insurer?
Yes. Tell us who should receive the pages and the summary, and we send the same set to each of them.
Can you do the repairs as well?
Yes. Each repair gets a written price per unit, and the board or owner approves the list before we start any of it.
Plan a round of the building
List the buildings on the contact page with roughly how many gas and wood units each holds, and we come back with a plan and a total.
Call (323) 529-8149